Study of voltage harmonic contamination in the (MV) cables with metallic screen of multipoint earth and sheath voltage limiter in the micro grid networks
نویسندگان :
Javad Behkesh noshahr
1
1- شرکت توزیع نیروی برق اردبیل
کلمات کلیدی :
Harmonic contamination،Metallic screen،Eddy current،harmonic emission،renewable sources of energy
چکیده :
In recent years, with the growth of using renewable energy sources and their connection to the network, some unexpected problems in electrical equipment are observed. By integrating renewable energy sources with the ability to produce megawatts and two-way electrizing the cables, we observe the complexity of utilization issues, damage and cable failure arising from harmonic contamination. Renewable energy sources, due to the use of power electronics equipment’s and static converters with high switching frequency in their manufacturing technology, are a potential source of voltage and current harmonic contamination. Generally, in the medium voltage cables to reduce and remove electric field, the metallic screen method with single-point, double-point, multipoint earth with the sheath voltage limiter or cross bonding is used. However, use of multipoint method earth method with sheath voltage limiter is more efficient than the other methods and reduces the rate of losses in the metallic screen and the number of eddy current loops in the metallic screen circuit, but this method results in increase of harmonic emission in the main conductor voltage of cable. By integrating renewable sources of energy and changing the operating conditions, especially the two-way electrizing of equipment’s and increase of the harmonious contamination arising from connection of such resources in micro grids, it is necessary to evaluate the effects of such resources on the performance of sensitive network equipment’s such as cables and shields. In this article it has been attempted, first, the matrix parameters of RLC of three-phase cable (monopole) are calculated according the conduction and insulation features. Then the rate of increase of voltage harmonic contamination in the main conductor of cable is examined by multipoint earthing method and sheath voltage limiter with presence of renewable sources of energy. Also the rate of annual energy losses in the metallic screen is calculated by the two techniques of multipoint earthing equipped to sheath voltage limiter and cross bonding is calculated and compared. Results show that in the multipoint method with sheath voltage limiter the rate of voltage harmonic contamination has increased 55%in the cable main conductor. While, the rate of losses energy in the metallic screen has reduced 71% compared to the cross bonding method. It is necessary to mention that in both methods the amount of the induced voltage in the metallic screen of cable is within the range determined by provisions of 523-05-01. Simulation for this study has been performed in the Matlab/Simulink setting and in a real time form.
لیست مقالات
لیست مقالات بایگانی شده
طرح هماهنگی حفاظتی تطبیقی برای ریزشبکه های حلقوی دارای منابع انرژی تجدید پذیر با در نظر گرفتن تغییر در توپولوژی شبکه
عبدالرضا قلی پور - مهدی اخباری - محمد زمان جلویان
بررسی قابلیت اطمینان سیستم قدرت در حضور مزارع بادی و سیستمهای ذخیرهساز انرژی
امیدرضا لک - سعید موثقی - احسان باقری
مدلسازی اثر خودمختاری تطبیقی در امنیت سایبری شبکههای هوشمند با استفاده از تئوری بازیها
علیرضا فریدونیان
پیش بینی احتمالاتی رفتار مشترکان برق در برابر مشوق های مالی جهت برنامه های پاسخ گویی بار با استفاده از منطق فازی
اسماء کریمی نوبندگانی - حمیدرضا کریمی فرد - سعید نژادفردجهرمی - محمود روستایی
طراحی و ساخت دستگاه پرتابل دیاگ چراغهای تخلیه شدت بالا(HID)
حمید صفری - محسن ابوترابی - علی قمشه - محمد جواد نجاتی باغدار
راهکارهای حفاظت از جان در مقابل حوادث برقگرفتگی ناشی از تیرهای برق با بهرهگیری از فناوری تیرهای فولاد–کامپوزیتی در شرایط غیرمترقبه
بهمن ابراهیم زاده - تقی سامی
شناسایی و طبقه بندی روزهای حادثه بزرگ در محاسبات شاخصهای قابلیت اطمینان شبکههای توزیع برق
حسین امیری - بهنام فاتحی - مهدی شفیعیان - محمد امیرزاده
کاربرد هوش مصنوعی برای ارزیابی ریسک بلادرنگ با پردازش تصویر در ایمنی محیط کار شبکه های توزیع
جواد بهکش نوشهر
مدیریت خاموشی های بی برنامه شبکه فشار متوسط بر اساس روش تحلیل علل ریشه ای با هدف بهبود پایداری شبکه- مطالعه موردی منطقه برق بعثت تهران
رامین اعظمی - عبدالحمید هادی پور مطلق
بازآرایی شبکه فشار متوسط توزیع با هدف بهبود قابلیت اطمینان و کیفیت توان (مطالعه موردی روی شبکه توزیع فشار متوسط شهرستان قاینات)
اسماعیل فیروزی - سید مهدی نوربخش - حمید فلقی
بیشتر
محل شرکت
ثمین همایش، سامانه مدیریت کنفرانس ها و جشنواره ها - نگارش 43.9.1