Study of voltage harmonic contamination in the (MV) cables with metallic screen of multipoint earth and sheath voltage limiter in the micro grid networks
نویسندگان :
Javad Behkesh noshahr
1
1- شرکت توزیع نیروی برق اردبیل
کلمات کلیدی :
Harmonic contamination،Metallic screen،Eddy current،harmonic emission،renewable sources of energy
چکیده :
In recent years, with the growth of using renewable energy sources and their connection to the network, some unexpected problems in electrical equipment are observed. By integrating renewable energy sources with the ability to produce megawatts and two-way electrizing the cables, we observe the complexity of utilization issues, damage and cable failure arising from harmonic contamination. Renewable energy sources, due to the use of power electronics equipment’s and static converters with high switching frequency in their manufacturing technology, are a potential source of voltage and current harmonic contamination. Generally, in the medium voltage cables to reduce and remove electric field, the metallic screen method with single-point, double-point, multipoint earth with the sheath voltage limiter or cross bonding is used. However, use of multipoint method earth method with sheath voltage limiter is more efficient than the other methods and reduces the rate of losses in the metallic screen and the number of eddy current loops in the metallic screen circuit, but this method results in increase of harmonic emission in the main conductor voltage of cable. By integrating renewable sources of energy and changing the operating conditions, especially the two-way electrizing of equipment’s and increase of the harmonious contamination arising from connection of such resources in micro grids, it is necessary to evaluate the effects of such resources on the performance of sensitive network equipment’s such as cables and shields. In this article it has been attempted, first, the matrix parameters of RLC of three-phase cable (monopole) are calculated according the conduction and insulation features. Then the rate of increase of voltage harmonic contamination in the main conductor of cable is examined by multipoint earthing method and sheath voltage limiter with presence of renewable sources of energy. Also the rate of annual energy losses in the metallic screen is calculated by the two techniques of multipoint earthing equipped to sheath voltage limiter and cross bonding is calculated and compared. Results show that in the multipoint method with sheath voltage limiter the rate of voltage harmonic contamination has increased 55%in the cable main conductor. While, the rate of losses energy in the metallic screen has reduced 71% compared to the cross bonding method. It is necessary to mention that in both methods the amount of the induced voltage in the metallic screen of cable is within the range determined by provisions of 523-05-01. Simulation for this study has been performed in the Matlab/Simulink setting and in a real time form.
لیست مقالات
لیست مقالات بایگانی شده
ساخت تیغه بای پس کت اوت فیوزی جهت تعویض فیوز لینک در شرکت توزیع برق شهرستان اصفهان
محمدرضا فخاری - حجت الله شمس - فرزاد الیادرانی - عباسعلی الیادرانی
پیاده سازی عملی نرم افزار انجام مطالعات هماهنگی حفاظتی شبکه های توزیع مبتنی بر داده های GIS
حمیدرضا آقائی - معین عابدینی - میلاد بیک بابایی - مهدی داورپناه - وحید متقی - محمدجواد جوهری - حبیب اله مظاهری
Investigating the impact of technology on renewable electricity energy consumption in Iran
Najme Mohamadi - Bahram Sahabhi - Hassan Heydari - Hossein Sadeghi Saqdel
الگوریتم پایش هوشمند الکتریکال GIS (سامانه سپهر)
مهرداد دادخواه - وحید متقی - سلمان مهدوی منش - معصومه رشیدی
بهینه سازی تعداد و مسیرهای پیمایش ماموران قرائت خوان کنتور در سطح شهر با استفاده از الگوریتم بهینه سازی بهبود یافته مبتنی بر آموزش و یادگیری
حمیدرضا مسرور - محسن باقری - مژده فخارزادگان
Analyzing Electricity Market Data By Method Multidimensional Data Analysis Using Power BI Software
Javad Shabbidar - Sasan Houshangifar - Sara Salehi - Mehran Nasr
آنالیز احتمالاتی ریسک شکست عایقی ترانسفورماتورهای فشار متوسط هوایی و برقگیرهای آن با توجه به مقدار مقاومت زمین حفاظتی
محمدرضا فرهادی - یحیی جمشیدی - جهانگیر رفیعی - پژمان سعیدی نژاد
امکان سنجی حذف شاخک جرقهگیر در ترانسفورماتورهای توزیع هوایی
محمدرضا فخاری - سعید قربانی - مهران نصر - قاسم رضایی - مهدی ایکدری
برنامه ریزی بازدید و تعمیرات فیدرهای فشار متوسط امور برق منطقه 9 شرکت توزیع برق شهرستان اصفهان به روش TOPSIS
قاسم رضائی چمگردانی - رسول حلوائی دولت آبادی - حمیدرضا آقائی - سعید افلاکیان - محمدرضا فخاری - محمد ابراهیمی
شبیه سازی و تحلیل عملکرد حالت گذرای جرقه گیرهای شاخکی مرسوم و مجهز به قطع کننده جریان خطا در شبکه توزیع
محمدصادق آزمون - محمود روستایی
بیشتر
ثمین همایش، سامانه مدیریت کنفرانس ها و جشنواره ها - نگارش 41.3.1