Study of voltage harmonic contamination in the (MV) cables with metallic screen of multipoint earth and sheath voltage limiter in the micro grid networks
نویسندگان :
Javad Behkesh noshahr
1
1- شرکت توزیع نیروی برق اردبیل
کلمات کلیدی :
Harmonic contamination،Metallic screen،Eddy current،harmonic emission،renewable sources of energy
چکیده :
In recent years, with the growth of using renewable energy sources and their connection to the network, some unexpected problems in electrical equipment are observed. By integrating renewable energy sources with the ability to produce megawatts and two-way electrizing the cables, we observe the complexity of utilization issues, damage and cable failure arising from harmonic contamination. Renewable energy sources, due to the use of power electronics equipment’s and static converters with high switching frequency in their manufacturing technology, are a potential source of voltage and current harmonic contamination. Generally, in the medium voltage cables to reduce and remove electric field, the metallic screen method with single-point, double-point, multipoint earth with the sheath voltage limiter or cross bonding is used. However, use of multipoint method earth method with sheath voltage limiter is more efficient than the other methods and reduces the rate of losses in the metallic screen and the number of eddy current loops in the metallic screen circuit, but this method results in increase of harmonic emission in the main conductor voltage of cable. By integrating renewable sources of energy and changing the operating conditions, especially the two-way electrizing of equipment’s and increase of the harmonious contamination arising from connection of such resources in micro grids, it is necessary to evaluate the effects of such resources on the performance of sensitive network equipment’s such as cables and shields. In this article it has been attempted, first, the matrix parameters of RLC of three-phase cable (monopole) are calculated according the conduction and insulation features. Then the rate of increase of voltage harmonic contamination in the main conductor of cable is examined by multipoint earthing method and sheath voltage limiter with presence of renewable sources of energy. Also the rate of annual energy losses in the metallic screen is calculated by the two techniques of multipoint earthing equipped to sheath voltage limiter and cross bonding is calculated and compared. Results show that in the multipoint method with sheath voltage limiter the rate of voltage harmonic contamination has increased 55%in the cable main conductor. While, the rate of losses energy in the metallic screen has reduced 71% compared to the cross bonding method. It is necessary to mention that in both methods the amount of the induced voltage in the metallic screen of cable is within the range determined by provisions of 523-05-01. Simulation for this study has been performed in the Matlab/Simulink setting and in a real time form.
لیست مقالات
لیست مقالات بایگانی شده
شناسایی مزارع غیرمجاز استخراج رمز ارز به کمک داده کاوی کنتورهای هوشمند مبتنی بر منطق فازی
حامد چنارانی - مهران قاسم پور - سید محمد احمدی - حسین دلاوری پور
آسیبشناسی کارکردهای مدیریت منابع انسانی در شرکت توزیع نیروی برق شهرستان اصفهان
احمد نادعلی - مسعود جمشیدیان - مینا حجاری
جایابی بهینه برقگیرهای حفاظتی درشبکه های توزیع فشارمتوسط با در نظر گرفتن هماهنگی عایقی تجهیزات
محمدصادق آزمون - حمیدرضا جلایر - مهدی زارع خفری - مهدی شفیعیان - سعید نژادفردجهرمی - محمود روستایی
چالش های پیش روی شرکت های توزیع برق در استفاده از داده کاوی در تحلیل خاموشی های بی برنامه
محمدرضا بهمنش فر - مهدی پیرپیران نجف آبادی - محمدرضا مومنیان
تحلیل علل ریشه ای عیوب ناشی از اثر رطوبت بر پست های کمپکت شرکت توزیع نیروی برق استان گیلان و ارائه راهکارهای عملی جهت جلوگیری از وقوع مجدد آنها
آرین سلمان پور - سیدمصطفی سیدی - اسماعیل خوش مسلک
تخمین احتمالاتی قابلیت بارگذاری خطوط شبکه توزیع در حضور خودروهای برقی و توربین های بادی
اسماء کریمی نوبندگانی - حمیدرضا کریمی فرد - سعید نژادفردجهرمی - محمود روستایی
طراحی و ساخت تابلو اتوریکلوزر برای کلید قدرت سکشنالایزرهای معیوب
مهدی جباری وند
نقش پایش وضعیت برای نگهداری و تعمیرات، در طول عمر کلیدهای شبکههای توزیع
حسام فیاضی - علی اصغر رضی کاظمی - علیرضا فریدونیان
خوشه بندی خودکار پروفیل بار مشترکین از طریق داده های کنتور هوشمند با استفاده از الگوریتم شبکه عصبی مصنوعی
محسن شهسواری - محسن معتمدی فرد - حجت اله شمس
اهش طول عمر خازن های فشار متوسط در شبکه های توزیع ناشی از بهره برداری
علی گودرزی - ایوب دهقان - مهدی بوستانی - مهدی زارع خفری
بیشتر
محل شرکت
ثمین همایش، سامانه مدیریت همایش ها و جشنواره ها - نگارش 44.9.10