Study of voltage harmonic contamination in the (MV) cables with metallic screen of multipoint earth and sheath voltage limiter in the micro grid networks
نویسندگان :
Javad Behkesh noshahr
1
1- شرکت توزیع نیروی برق اردبیل
کلمات کلیدی :
Harmonic contamination،Metallic screen،Eddy current،harmonic emission،renewable sources of energy
چکیده :
In recent years, with the growth of using renewable energy sources and their connection to the network, some unexpected problems in electrical equipment are observed. By integrating renewable energy sources with the ability to produce megawatts and two-way electrizing the cables, we observe the complexity of utilization issues, damage and cable failure arising from harmonic contamination. Renewable energy sources, due to the use of power electronics equipment’s and static converters with high switching frequency in their manufacturing technology, are a potential source of voltage and current harmonic contamination. Generally, in the medium voltage cables to reduce and remove electric field, the metallic screen method with single-point, double-point, multipoint earth with the sheath voltage limiter or cross bonding is used. However, use of multipoint method earth method with sheath voltage limiter is more efficient than the other methods and reduces the rate of losses in the metallic screen and the number of eddy current loops in the metallic screen circuit, but this method results in increase of harmonic emission in the main conductor voltage of cable. By integrating renewable sources of energy and changing the operating conditions, especially the two-way electrizing of equipment’s and increase of the harmonious contamination arising from connection of such resources in micro grids, it is necessary to evaluate the effects of such resources on the performance of sensitive network equipment’s such as cables and shields. In this article it has been attempted, first, the matrix parameters of RLC of three-phase cable (monopole) are calculated according the conduction and insulation features. Then the rate of increase of voltage harmonic contamination in the main conductor of cable is examined by multipoint earthing method and sheath voltage limiter with presence of renewable sources of energy. Also the rate of annual energy losses in the metallic screen is calculated by the two techniques of multipoint earthing equipped to sheath voltage limiter and cross bonding is calculated and compared. Results show that in the multipoint method with sheath voltage limiter the rate of voltage harmonic contamination has increased 55%in the cable main conductor. While, the rate of losses energy in the metallic screen has reduced 71% compared to the cross bonding method. It is necessary to mention that in both methods the amount of the induced voltage in the metallic screen of cable is within the range determined by provisions of 523-05-01. Simulation for this study has been performed in the Matlab/Simulink setting and in a real time form.
لیست مقالات
لیست مقالات بایگانی شده
اولویت بندی بهینه تعویض پایه های فرسوده در نرم افزار PM جهت بهبود تاب آوری شبکه توزیع استان فارس
محمود روستایی - محسن بنده خدا - شاهرخ آزرم - حمیدرضا جلایر - مهدی زارع خفری
بررسی عوامل ارگونومیکی موثر در بروز حوادث ناشی از کار در ارتفاع
فاطمه نظری - سعید چترآذر - علی احسان اشرفی - ایرج محمد فام - امیر حسین لطفی
ارزیابی هارمونیکی مشترکین خانگی در شبکه توزیع (مطالعه میدانی)
محمد کیان - هادی افکار - محمد حسن احمدی
تشخیص خطای سوییچ در مبدل تمام پل و رفع آن با تغییر توپولوژی به منظور استمرار عملکرد در سیستمهای خورشیدی
شاهرخ آزرم - یوسف نیازی - راحله ذیگلری - محمدامین بینا - ابوالفضل شعبانی اصل - غلامعلی کریمی
اثرات مخرب خاموشیهای کمبود تولید بر روی عایق تجهیزات فشارمتوسط
محمدرضا فخاری - مهدی ایکدری - سعید افلاکیان - قاسم رضایی - مهدی علائی - محسن رضوانی
پیاده سازی نگهداشت تجهیزات شبکه توزیع مبتنی بر قابلیت اطمینان با استفاده از شاخصهای بحرانی فنی-مالی تجهیز
سید مهیار نجفی نژاد - محمد ابراهیم طیبی عراقی - حسین قاسمی - کامبیز ناظریان
ارائه طرحی جدید برای تشخیص خطا، ایزوله سازی و بازیابی سرویس (خودترمیمی) در فیدرهای پرعارضه استان تهران
کیوان چوپانی - محمد عباسی - حسین سوری - زهرا محمدی - مهدی خزائی
حداقل سازی تلفات توان و هزینه بهره برداری در شبکه توزیع در حضور منابع تولید پراکنده و باتریها
رامین صرفی - حسین لطفی - محمد برهان علمی
سیستم ارتباطی هوشمند چراغهای معابر با استفاده از سیم فاز شب به عنوان بستر ارتباطی
یوسف نیازی - پگاه یاوری - راحله ذیگلری - سعدی نیازی - مهسا آزرم
طراحی و توسعه فازیاب مبتنی بر ماژول GIS
امید دریجانی - نادر خواجه پور - رضا مسعودی
بیشتر
ثمین همایش، سامانه مدیریت کنفرانس ها و جشنواره ها - نگارش 41.3.1