Study of voltage harmonic contamination in the (MV) cables with metallic screen of multipoint earth and sheath voltage limiter in the micro grid networks
نویسندگان :
Javad Behkesh noshahr
1
1- شرکت توزیع نیروی برق اردبیل
کلمات کلیدی :
Harmonic contamination،Metallic screen،Eddy current،harmonic emission،renewable sources of energy
چکیده :
In recent years, with the growth of using renewable energy sources and their connection to the network, some unexpected problems in electrical equipment are observed. By integrating renewable energy sources with the ability to produce megawatts and two-way electrizing the cables, we observe the complexity of utilization issues, damage and cable failure arising from harmonic contamination. Renewable energy sources, due to the use of power electronics equipment’s and static converters with high switching frequency in their manufacturing technology, are a potential source of voltage and current harmonic contamination. Generally, in the medium voltage cables to reduce and remove electric field, the metallic screen method with single-point, double-point, multipoint earth with the sheath voltage limiter or cross bonding is used. However, use of multipoint method earth method with sheath voltage limiter is more efficient than the other methods and reduces the rate of losses in the metallic screen and the number of eddy current loops in the metallic screen circuit, but this method results in increase of harmonic emission in the main conductor voltage of cable. By integrating renewable sources of energy and changing the operating conditions, especially the two-way electrizing of equipment’s and increase of the harmonious contamination arising from connection of such resources in micro grids, it is necessary to evaluate the effects of such resources on the performance of sensitive network equipment’s such as cables and shields. In this article it has been attempted, first, the matrix parameters of RLC of three-phase cable (monopole) are calculated according the conduction and insulation features. Then the rate of increase of voltage harmonic contamination in the main conductor of cable is examined by multipoint earthing method and sheath voltage limiter with presence of renewable sources of energy. Also the rate of annual energy losses in the metallic screen is calculated by the two techniques of multipoint earthing equipped to sheath voltage limiter and cross bonding is calculated and compared. Results show that in the multipoint method with sheath voltage limiter the rate of voltage harmonic contamination has increased 55%in the cable main conductor. While, the rate of losses energy in the metallic screen has reduced 71% compared to the cross bonding method. It is necessary to mention that in both methods the amount of the induced voltage in the metallic screen of cable is within the range determined by provisions of 523-05-01. Simulation for this study has been performed in the Matlab/Simulink setting and in a real time form.
لیست مقالات
لیست مقالات بایگانی شده
بررسی اثر مقاومت زمین شبکه توزیع بر میزان شناوری ولتاژ مشترکین در شرایط قطع هادی خنثی
محمد کیان - هادی افکار - بهزاد بهدانی
Optimum Placement of Reactive Power Compensation Resources in Unbalanced Power Distribution Network with the Aim of Reducing Losses and Improving Voltage Profile
Mohammadreza Mousavikhademi - Ebrahim Kzaemi - Mehdi Zareian Jahromi
Asset Management and Maintenance Orientations in Electrical Distribution Networks: A Review
Hesam addin Yousefian - Adel Kazemi - Rasoul Abdali
طراحی شاخص پایش و نگهداشت پیشگویانه شبکه فشار متوسط هوایی و ارزیابی اقتصادی آن با رویکرد مدیریت دارایی های فیزیکی
مصطفی دلبری - عباس آذری - بهمن صداقت - امیر کاظمی
شناسایی دستگاه های استخراج رمزارز غیرمجاز و کاهش تلفات غیرفنی شبکه توزیع برق با استفاده از روش های هوشمند و بدون نظارت
حسین قاسمی - الناز شهرابی فراهانی
کدگذاری و نصب برچسب رمزینه پاسخ سریع روی لوازم اندازه گیری در شرکت توزیع نیروی برق استان خراسان رضوی به شیوه ای نوین
ناصر نایب - مهدی شفیعی زاده - مهدی دهقان - احمد اسدی
مکان یابی بهینه سیستم های تولید همزمان برق و حرارت جهت بهبود تاب آوری شبکه توزیع برق استان فارس پس از وقوع سیل
محمود روستایی - سعید نژادفرد جهرمی - طاهر نیکنام
برآورد و بررسی تأثیر مصرف تعرفه های برق در رشد اقتصادی ایران در سال 1401
محسن پیام فر - علی خدری
تجهیزات و سیستم های نوین ایمنی در حوزهHSE
محمد مصطفوی
طراحی و مدلسازی سامانه دوکاناله تشخیص سریع قوس الکتریکی بهمنظور ارتقای ایمنی و کاهش انرژی حادثه در شبکههای توزیع برق
محسن نیک انجام - علی سهرابی بیدار
بیشتر
محل شرکت
ثمین همایش، سامانه مدیریت کنفرانس ها و جشنواره ها - نگارش 43.0.1